Five Key Factors Affecting The Accuracy Of The Load Cell

  • 2021-04-05

In terms of a load cell, what is the definition of accuracy? What conditions or factors are most important for the accuracy of the load cell? Each load cell is different and is designed with different specifications in mind. It is important for engineers to understand the different factors that affect the accuracy of a load cell and how to ensure that the load cell is best suited to their needs. Here are five factors to consider. The temperature in the air can affect the ability of the load cell to provide accurate measurements because of their sensitivity. Each load cell has a temperature point at which accuracy is affected, but many load cells are designed to deal with extreme temperatures. When selecting a load cell, the engineer needs to tell the load cell manufacturer at what temperature they expect the load to operate. Humidity does not affect the load cell as directly as temperature, but over time it can affect the accuracy of its data. Weighing sensors operating in high humidity environments must be properly designed for this task. Creep is the change in accuracy caused by applying pressure to the load cell at a constant load, while all other environmental conditions and variables remain constant. Creep is caused by the slow deformation of a material under constant load. Sideload and eccentric load is not suitable for the measurement of the load cell, which will reduce the service life of the sensor and make the measurement results distorted. The load cell usually measures the force in only one direction. The installation will affect the interaction between the load cell and the part under test. If the installation is off-center, the readings will be inaccurate. Be sure to follow the installation instructions for the load cell.


Bently Nevada Siemens Triconex
3500/42 16267-1/4 Triconex 4000042-120
TK3-2E W89070-U2321-A6 Triconex 219179
991-25-70-01-01 U-55N Triconex 2201 CM 2201
991-01-XX-01-01 U-08B Triconex 2351
990-08-XX-01-00 TI435-CPU Triconex 2352
990-05-70-01-01 T89620-E3298-F050/MS-DOS Triconex 2361
990-05-50-02-01 T89120-E3087-H Triconex 2381
9200-01-05-10-00 SSN-BG89A010563 Triconex 2401
88199-01 SMP-E431-A6 Triconex 2401L
88194-01 S MAR7517679 Triconex 2451
88149-01 S MAR5515395 Triconex 2481
84933-02 RMS-TSG-TZ-C Triconex 2551
81228-01(3300) RMS-TIG-TZ-C Triconex 2551 7300057-100
79748-01 RD63F200 Triconex 2551 7400056-110
79532-01 R15E02A186 Triconex 2551 7400058-110
79522-01 QLSAMBAN Triconex 2553
78462-02 QLCCM24AAN A5E00282046 A5E00282046/06 Triconex 2553 7400056-310

Honeywell DCS
GE Fanuc PLC
Foxboro Module
Yokogawa Electric
Ovation DCS
Schneider PLC
Siemens PLC
Emerson Module
Hima DCS Modules
Allen Bradley PLC
Bently Nevada PLC
ABB PLC
Phoenix PLC

© Copyright: Jak PLC All Rights Reserved.

Jak PLC is not owner of the brands/manufacturers featured on this website. Brand names and trademarks featured are the property of their respective 

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.