Honeywell PKS system

  • 2021-06-29
The standard industrial Ethernet network used by the PKS system is the factory information network, which is the most widely used Ethernet in the field of office automation. The STATION Omni-directional operation station in the PKS system provides a standard Ethernet interface, which makes the whole plant management and control integration easy. STATION workstation uses WINDOWS 2000 as the operating platform, and PKS is designed as a working model in which the lower-level controller CPM reads server data through SQL database and then conducts two-way communication with STATION workstation. Both the server and the workstation run in the WINDOWS 2000 environment, which has more functions than the WINDOWS operating system. The CONTROL NET communication network of the PKS system adopts ISO802.4 formulated by ISO (International Organization for Standardization) and IEEE802. 4 open system interconnection standards formulated by IEEE (American Institute of Electrical and Electronics Engineers), based on ISO's seven-layer OSI model. As the basis, follow the MPA (Factory Automation Protocol) network standard, token bus network communication. Any computer equipped with PKS system Station version software can be connected to a standard Ethernet switch interface through a network cable to become a Station workstation.

Openness does have many benefits, but while considering openness, the security and reliability of the system must first be fully considered. The loss caused by the breakdown of the production process or the accident may be much higher than the cost saved by the open choice of products. At the same time, note that when selecting system equipment, first determine the requirements of the system, and then select the necessary equipment according to the requirements. Try not to equip some unnecessary functions, especially the selection of network functions and peripherals must be cautious. For example, when we choose to open the network, the possibility of being attacked by viruses or hackers will increase; we choose a wealth of peripherals such as optical drives or floppy drives, and the USB interface provides operators with loading irrelevant software (such as games, etc.) Opportunity to wait. These will lead to system paralysis or other fatal failures.

IP91-A KJ3002X1-BG1 T9451 3500/90 125728-01
FC81-A KJ3002X1-BB1 T9802 3500/42 125672-02
MX3*D KJ3001X1-BB1 T9852 3500/42M 140734-02
ST2*D KJ3004X1-EA1 T9300 125768-01
VM1*D KJ4001X1-BA2 T9100 126615-01
ST3*A KJ4001X1-BE1 T9832 125736-01
PAC*A KJ3002X1-BC1 T8403 125840-01
NM29*A KJ3002X1-BF1 T8311 128240-01
ALU4*D KJ3001X1-BJ1 T8403 125760-01
CTL4*B KJ4001X1-CG1 T8440B 102351-04-01
SIF2*A KJ4001X1-CH1 T8193 3300/12
GD10*A KJ2002X1-BA1 T8311 3300/03
NCU4*A KJ3004X1-BA1 T8442 3300/16
MS05*B KJ1501X1-BB1 T8151B 3300/20
MDK2-S1 KJ4001X1-CA1 T8130 78462-01
MDK1*B KJ4001X1-CC1 T8431 3300/05-22-00-00

Honeywell DCS
GE Fanuc PLC
Foxboro Module
Yokogawa Electric
Ovation DCS
Schneider PLC
Siemens PLC
Emerson Module
Hima DCS Modules
Allen Bradley PLC
Bently Nevada PLC
ABB PLC
Phoenix PLC

© Copyright: Jak PLC All Rights Reserved.

Jak PLC is not owner of the brands/manufacturers featured on this website. Brand names and trademarks featured are the property of their respective 

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.