How To Select The Pressure Sensor?
For example, the situation is different when the sensor is used to measure the pressure of gas compared with that of a liquid. Gas is a compressible fluid. When increased, it will store a certain amount of compression energy. When decompressed, it will be released with kinetic energy to exert a shock wave on the sensor elastic film. The pressure sensor is required to have a large overload capacity. The liquid is an incompressible fluid. When the pressure sensor is installed, if the screw is tightened and there is no compression space, the liquid pressure can rise beyond the pressure resistance limit of the elastic film, leading to the rupture of the elastic film. As this situation occurs frequently, the pressure sensor is also required to have a greater overpressure capacity. When the working environment of the pressure sensor is bad, such as large vibration, impact, and large electromagnetic interference, more strict requirements are put forward for the sensor. Not only the overpressure capacity is strong, but also the mechanical seal is reliable, anti-loosening, and the sensor is installed correctly. The leads, pins, and external wires of the sensor itself shall be electromagnetic shielded and well-grounded. In addition, the compatibility of the pressure sensor with the measured flow medium should be considered. For example, the elastic membrane structure of the sensor should be separated from the corrosive medium. At this time, the stainless steel corrugated sleeve sensor is adopted. The silicon oil is used as the pressure transmission medium in the sensor. When the sensor detects the pressure of flammable and explosive media, the small excitation current is used to prevent the spark and Mars from being generated when the elastic film ruptures, and to increase the pressure resistance of the pressure sensor coat.
GE Fanuc | Bently Nevada | Siemens |
IC695PSA040 | 3500/42 | 16267-1/4 |
IC670MDL241 | TK3-2E | W89070-U2321-A6 |
UR9EH | 991-25-70-01-01 | U-55N |
IC693CHS397C | 991-01-XX-01-01 | U-08B |
369-HI-R-M-0-0-0-E | 990-08-XX-01-00 | TI435-CPU |
IC698CPE010 | 990-05-70-01-01 | T89620-E3298-F050/MS-DOS |
DS3800HISA1A1A | 990-05-50-02-01 | T89120-E3087-H |
IC693ALG221 | 9200-01-05-10-00 | SSN-BG89A010563 |
DS200DCFBG2BNC | 88199-01 | SMP-E431-A6 |
IS200SPIDG1ABA | 88194-01 | S MAR7517679 |
IC698CRE020CA | 88149-01 | S MAR5515395 |
IS200VR0CH1BBR | 84933-02 | RMS-TSG-TZ-C |
IC697CPX935-FD | 81228-01(3300) | RMS-TIG-TZ-C |
IC200MDL750H | 79748-01 | RD63F200 |
IC697CPU781 | 79532-01 | R15E02A186 |
V7768-320000 | 79522-01 | QLSAMBAN |
IC200ALG322 | 78462-02 | QLCCM24AAN A5E00282046 A5E00282046/06 |
IC200PWR101 | 78462-01 | QLCCM22AAN 16418-31 |
IS230STCIH6A | 75619 302-EL30 | QLCAIAAN |
IC670ALG630 | 71573 306-EL30 | PS02-3005 |
IS200EDCFG1A | 47042 308 EL30 | PS02-3001V5.00 |
IS210AEPSG1A | 3500/94 | E10433-E0308-H110 |
Previous :
Do You Know HIMA?Next :
New Quantum Sensors Measure And Control Qubits© Copyright: Jak PLC All Rights Reserved.