The Internal Dismantling Of Schneider PLC Is Really Amazing(2)

  • 2021-06-07

Let's take a look at the basic composition of PLC

Simple understanding, PLC is like a small computer, CPU is responsible for processing data, including logical operations, timing, counting, arithmetic operations and transmission, communication networking, compiling the compiled program, executing commands, and transmitting the results to the output terminal . The PLC's memory (memory) consists of two parts. One is the ROM that stores the system program. The content in this read-only memory is solidified by the PLC before leaving the factory and cannot be changed by the user. The other is the readable storage for the user program and working status data. Write RAM memory.
Then there are input and output units and I/O expansion interfaces, which are responsible for connecting with external devices. Finally, there is a power supply module, which converts the external input power into the DC power required by the PLC's CPU, memory, input and output interfaces and other internal circuits, such as 24V, after processing.

Compared with other control equipment, the biggest feature of PLC is that it is sturdy, simple, reliable, and durable. Therefore, PLC must be used in the selection of processor and memory, PCB board circuit layout, power supply unit and communication loop design, and structural design. Follow these characteristics. It can be said that whether a PLC can run stably and reliably for a long time determines its quality. Therefore, we mainly look at how the reliability of PLC is designed.
First, we turn over the M262, we can see that there are 4 screws at the bottom, but they are hexagon sockets, and the common flat-head and Phillips screwdrivers cannot be unscrewed. This can also prevent some people from opening the PLC at will. We easily unscrewed 4 screws with a special Allen screwdriver.

However, although the 4 screws have been unscrewed, the bottom cover and the upper cover of the M262 are still tightly fixed together with a ring of buckles. You can only use a flat-blade screwdriver to push in one by one and then forcefully open the bottom cover.

After the buckles are loosened one by one, the bottom cover and the top cover are separated smoothly.


PCI-85 TSXLES65 140DDI35300
SCTUST21 TSXMFPP004M 140DDI35310
TCSESM043FG2UD TSXP4720 140DDI84100
TCSESM083F2CUO TSXP47455 140DDI85300
TSX3721001 TSXP57153M 140DDM39000
TSX4740 TSXP57203M 140DDO35300
TSXAEM1613 TSXP67455 TSX6740 140DDO35301
TSXDEY16D2 USP2I 140DDO35310
TSXDSZ32R5 XBTF034510 140DDO36400
TSXETZ410 XBTGT2220 140DDO84300

Honeywell DCS
GE Fanuc PLC
Foxboro Module
Yokogawa Electric
Ovation DCS
Schneider PLC
Siemens PLC
Emerson Module
Hima DCS Modules
Allen Bradley PLC
Bently Nevada PLC
ABB PLC
Phoenix PLC

© Copyright: Jak PLC All Rights Reserved.

Jak PLC is not owner of the brands/manufacturers featured on this website. Brand names and trademarks featured are the property of their respective 

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.