The Ovation system is a model that integrates process control and enterprise management information technology with the most advanced computer and communication technology in the world today. It uses a high-speed, high-reliability, and high-open communication network, and has multi-task and multi-data acquisition control capabilities. The Ovation system uses the latest distributed and global-related databases to complete the configuration of the system. The globally distributed database distributes functions to multiple independent sites that can run in parallel, instead of focusing on a central processing unit, and does not affect system performance due to interference from other events.Ovation distributed control system network is composed of the mutually redundant network, data exchange station, operator station, engineer station, history station, controller, and other nodes. }Workstation: According to the different functions of the station, it is divided into several different functional stations, including database server DB, engineering server EWS, operator station OWS, historical report station OPH, other function stations OPC, etc. } Controller: As a control center, the controller adopts a redundant method to achieve maximum reliability and safety. The controller uses a PC-compatible real-time operating system (full 32-bit priority multitasking system), as well as a standard PC structure and a passive PCI/ISA bus interface.Operator station-complete the daily operation of the system} Server / engineer station-database and configuration tools} History / report station-historical data collection and report configuration and generation} OPC station-third-party system data connection1. All workstations can access the database and modify its content, but the permissions of the workstations are restricted due to the nature of the work.2. Both the database server and the history station are equipped with large-capacity hard disks. One is used to store database files in an offline state, and the other is used to store historical file information. If the database server is broken, all workstations can still operate normally, but cannot access the database files and modify the content; if the history station is broken, the historical information during this period of time cannot be collected, and real-time information can still be observed and collected.3. The history station collects information about historical points, not all points. You can add the desired point as a historical point through the software.
GPU200R
|
1794-IV32
|
51303294-100
|
51195155-100
|
RTXF18/RK926-007-AB
|
1404-M405A-DNT
|
51403422-150
|
MU-TAMR03 51309218-125
|
IEPAS02
|
1756-OX8I
|
51403988-150
|
51305890-175
|
INIIT03
|
1715-IB16D
|
51107403-100
|
51304477-100
|
GPU2000R
REG544
|
1715-OB8DE
|
80363969-150
|
51401642-150
|
GPU2000R
|
2711P-RW7
|
620-0086
|
51401560-100
|
RTXF18/RK926-115-AH
|
1794-IB16
|
621-0021
|
MC-TAIH02 51304453-150
|
1SAP281200R0001
TU582-S
|
1794-OB16
|
621-0022
|
MC-TAIL02 51304437-150
|
CD522
1SAP260300R0001
|
1756-BA1
|
621-9932
|
MC-TAMR03 51309218-175
|
1SAP111100R0270
TB511-ETH
|
1756-BA2
|
620-0059
|
MC-TLPA02 51309204-175
|
3BSE008516R1
AI810
|
1794-AENT
|
621-9935
|
MC-TAOY22 51204172-175
|
3BSE039293R1
AI880A
|
2711P-T6M3D
|
51401291-100
|
MC-TAMT03 51309223-175
|
3BSE028602R1
DO880
|
2711P-RN3
|
51400855-100
|
TC-IAH16I
|
SPDSI13
|
1769-PA2
|
51400667-100
|
8C-TAOXB1 S/N:0152303449
|
SPASI23
|
1769-IQ16
|
51400926-100
|
CC-PAIN01 S/N:M0151855604
|
SPDSO14
|
1769-ECR
|
51402089-100
|
8C-PAIMA1 51454473-175
|
IMSET01
|
1762-IQ32T
|
62795604-001
|
CC-PDIL01 51405040-175
|